Electric Cable MM0302519 - SPCC Cold-Rolled Steel Sheet الطرازات المتوافقة: C116
Metso · قطع غيار الكسارة الفكية ISO 9001 معتمد · توريد مباشر

Electric Cable

أرقام قطع OEM المتوافقة: MM0302519

Electric Cable

درجة المادة
SPCC Cold-Rolled Steel Sheet
الوزن
28.5 kg
الصلابة
N/A
الأبعاد
190×142×95 mm
الشهادة
ISO 9001:2015
مدة التسليم
15 أيام
الضمان
12 months from date of shipment

النموذج المتوافق

C116

التطبيق

Used in the electrical control, condition monitoring and operation circuits of the jaw crusher, providing start/stop, protective interlocking and operating parameter monitoring for safe and reliable electrical operation.

تعليمات التركيب

1. Before installation, check motor/sensor/switch models and voltage ratings, and confirm insulation resistance is acceptable; 2. Wire according to the drawing with clear wire numbers and firm crimps, and ensure reliable grounding; 3. After insulation tests pass, energize, jog to confirm correct rotation direction and action, then commission in interlocked mode.

الأسئلة الشائعة

Why does the motor trip immediately after starting?
Common causes: power phase loss, motor winding short circuit to ground or between turns, thermal relay set current too low, excessive starting load or mechanical jamming. First power off and measure insulation and DC resistance, then check mechanical rotation and the thermal relay setting.
What to do if the temperature/vibration sensor alarms but the equipment runs normally?
First verify the sensor range, check for loose wiring and whether the probe is properly attached to the measuring point, then compare data from other measuring points at the same position. If it is confirmed as sensor drift or false alarm, replace the sensor to avoid long-term protection bypass causing accidents.
The incoming voltage to the electrical cabinet is normal but the controls do not respond?
Check whether the control power fuse/circuit breaker has tripped, the emergency stop button is reset, the safety door limit switches and interlock circuits are closed, and the contactor coil is energized. Measure voltage section by section per the drawing to locate the fault.