Push button box 190.4506-00 - SPCC Cold-Rolled Steel Sheet Modelos compatibles: CJ612&JM1211
Sandvik · Piezas de desgaste y repuestos de trituradora de mandíbula ISO 9001 Certificado · Abastecimiento Directo

Push button box

Números de pieza OEM compatibles: 190.4506-00

Push button box

Grado material
SPCC Cold-Rolled Steel Sheet
Peso
34.5 kg
Dureza
N/A
Dimensiones
230×172×115 mm
Certificación
ISO 9001:2015
Plazo de entrega
15 días
Garantía
12 months from date of shipment

Modelo compatible

CJ612&JM1211

Aplicación

Used in the electrical control, condition monitoring and operation circuits of the jaw crusher, providing start/stop, protective interlocking and operating parameter monitoring for safe and reliable electrical operation.

Notas de instalación

1. Before installation, check motor/sensor/switch models and voltage ratings, and confirm insulation resistance is acceptable; 2. Wire according to the drawing with clear wire numbers and firm crimps, and ensure reliable grounding; 3. After insulation tests pass, energize, jog to confirm correct rotation direction and action, then commission in interlocked mode.

Preguntas frecuentes

Why does the motor trip immediately after starting?
Common causes: power phase loss, motor winding short circuit to ground or between turns, thermal relay set current too low, excessive starting load or mechanical jamming. First power off and measure insulation and DC resistance, then check mechanical rotation and the thermal relay setting.
What to do if the temperature/vibration sensor alarms but the equipment runs normally?
First verify the sensor range, check for loose wiring and whether the probe is properly attached to the measuring point, then compare data from other measuring points at the same position. If it is confirmed as sensor drift or false alarm, replace the sensor to avoid long-term protection bypass causing accidents.
The incoming voltage to the electrical cabinet is normal but the controls do not respond?
Check whether the control power fuse/circuit breaker has tripped, the emergency stop button is reset, the safety door limit switches and interlock circuits are closed, and the contactor coil is energized. Measure voltage section by section per the drawing to locate the fault.

Formulario de consulta

Complete el formulario y nuestro equipo le responderá en 24 horas con una cotización competitiva.

Push button box · 190.4506-00 · CJ612&JM1211
Solicitar cotización WhatsApp