kunci soket 705600098660 - SPCC Cold-Rolled Steel Sheet Model cocok: C100
Metso · Suku cadang aus & suku cadang crusher rahang ISO 9001 Bersertifikat · Pasokan Langsung

kunci soket

Nomor suku cadang OEM kompatibel: 705600098660

Wrench Socket untuk penghancur rahang Metso C100, No. OEM 705600098660. Desain diperkuat tugas berat untuk kondisi penghancuran benturan tinggi. Terbuat dari SPCC Cold-Rolled Steel Sheet. Berat: 22.5 kg. Dimensi: 150×112×75 mm. Dioptimalkan untuk material abrasif seperti batu pasir dan kerikil sungai.

Grade material
SPCC Cold-Rolled Steel Sheet
Berat
22.5 kg
Kekerasan
HB 170-230
Dimensi
150×112×75 mm
Sertifikasi
ISO 9001:2015
Waktu pengiriman
15 hari
Garansi
12 months from date of shipment

Model kompatibel

C100

Aplikasi

Digunakan pada rangkaian kontrol listrik, pemantauan kondisi, dan operasi jaw crusher, menyediakan start/stop, interlock proteksi, dan pemantauan parameter operasi untuk pengoperasian kelistrikan yang aman dan andal.

Catatan pemasangan

1. Sebelum pemasangan, periksa model motor/sensor/saklar dan rating tegangan, serta pastikan resistansi isolasi dapat diterima; 2. Lakukan pengkabelan sesuai gambar dengan nomor kabel yang jelas dan crimping yang kuat, serta pastikan pembumian yang andal; 3. Setelah uji isolasi lulus, beri daya, jalankan jog untuk memastikan arah putaran dan aksi benar, lalu komisioning dalam mode interlock.

Pertanyaan Umum

Why does the motor trip immediately after starting?
Common causes: power phase loss, motor winding short circuit to ground or between turns, thermal relay set current too low, excessive starting load or mechanical jamming. First power off and measure insulation and DC resistance, then check mechanical rotation and the thermal relay setting.
What to do if the temperature/vibration sensor alarms but the equipment runs normally?
First verify the sensor range, check for loose wiring and whether the probe is properly attached to the measuring point, then compare data from other measuring points at the same position. If it is confirmed as sensor drift or false alarm, replace the sensor to avoid long-term protection bypass causing accidents.
The incoming voltage to the electrical cabinet is normal but the controls do not respond?
Check whether the control power fuse/circuit breaker has tripped, the emergency stop button is reset, the safety door limit switches and interlock circuits are closed, and the contactor coil is energized. Measure voltage section by section per the drawing to locate the fault.

Formulir penawaran

Isi formulir di bawah dan tim kami akan merespons dalam 24 jam dengan penawaran kompetitif.

kunci soket · 705600098660 · C100
Minta penawaran WhatsApp